I’m looking for a smart home solution use two switches in my living room (EU), in order to make them just smart enough so I can control some devices. The setup isn’t very complex in itself, and I’m pretty sure it’s doable - I’m just unsure what I’d need in order to use these switches in a ‘smart’ capacity…

This is what I had in mind:

  • On-off switch, connected to a single light with three Hue filament bulbs. I’d like this one to always be powered, as to make them always controllable
  • On-off switch, which should be connected to a light which isn’t in use at all. Once this one is ‘smart’, I could control all other smart devices in the living room like a ‘turn off everything’-button.

I have a Hue bridge and a Home Assistant instance running in my home.

With regards to wife-approval-factor, I’d rather leave the original switches in place, but I’m open to suggestions. I hope one of you can steer me in the right direction.

Edit: if this isn’t the right community for the question, I’d understand, but I wasn’t sure where to put it otherwise… I’d be open to suggestions to that too.

  • AA5B@lemmy.world
    link
    fedilink
    English
    arrow-up
    1
    ·
    10 months ago

    Every wall switch I’ve seen (in US) has an attachment for a ground wire, except really ancient ones, and every “Romex” style wiring includes a ground wire

    My house is an older one with steel junction boxes, so those need to be grounded, but plastic boxes obviously do not.

    So, my experience may be limited but I’ve always seen switches grounded and always seen everything support grounding.

    As someone further up said, it’s the neutral that is the problem. I don’t know if it’s code or convention, but older wiring tends to use “switch loops” without a neutral, while more modern wiring is “pass through” and does. Even before smart switches, this was needed for things like lighted or programmable switches

    • xyguy@startrek.website
      link
      fedilink
      English
      arrow-up
      1
      ·
      10 months ago

      Current national electrical code in the US (since the 1980s) is a neutral in every switch box. Before then a switch loop was allowed so you see a lot of older construction with those.

      You also see newer construction with those where Uncle Dave™ decided it was easier to only have to run a wire down from the light rather than fish it up through the crawlspace, NEC be damned.

      • AA5B@lemmy.world
        link
        fedilink
        English
        arrow-up
        2
        ·
        edit-2
        10 months ago

        It’s also a matter of saving on the wiring. I may not be (quite) that Uncle Dave, but I really regret a few places I pulled wire for a switch loop without the extra conductor for a neutral.

        At the time, I rationalized it was already an improvement over what was there and I had no immediate use for the neutral. I believe the neutral wasn’t required by local code, only recommended, or I would have done it

        Of course now I’m cursing my choice, trying to decide whether I need to go back and do it over, or whether I even can practically since it’s a two person job and my buddy retired to Florida. Wiring I pulled many years ago was great for dimmers, more convenient switches, and extra three-ways, but not so great for smart switches

        Edit: looks like neutral wasn’t required until NEC 2011

        • xyguy@startrek.website
          link
          fedilink
          English
          arrow-up
          1
          ·
          10 months ago

          I didn’t realize it was that recent of an addition to the NEC. Weve only lived in super old houses where everything was always needing completely redone. I was usually replacing 2 conductor and cloth-jacketed stuff everywhere.

          That was around 2012 and I remember the electrician we hired at the time mentioned it being a thing so that makes sense.